O²T/FSp fire detector

O²T/So

Esser 802385

O²T/FSp Series IQ8Quad is the multi-technology detector with a built-in voice alarm device, a built-in flash lamp and a built-in alarm signalling device. It can be set to eight different levels of detection.
Multisensor detectors with two built-in optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation for detecting everything from smouldering fires to open fires with consistent response performance. Smoke sensor signal identification to ensure smoke classification and reduction of false alarms caused, for instance, by water vapour or dust. Each detector is provided with an integrated isolator. The alarm signaling device is activated by the control panel. No further short address needs to be allocated. It is programmed with tools 8000 as of software version 1.05.  Alarm tone / speech message programming (depending on type). For detectors with speech message and / or alarm tone function with up to five language options, up to 4 signals can be programmed. Two signals are reserved for alarm signaling and evacuation in the case of fire. Two further signals can be programmed for other events. Each signal can consist of up to four signal
components, enabling one signal to be programmed as a DIN tone combined with subsequent speech messages in three different languages. Alarm tones can be chosen from a table with various tone types. For application in schools, a break signal to signify the breaks between class can be activated. When the basic setting is selected, signals / signal components can be continuously repeated until the signaling function is interrupted by the control panel. They can also be programmed with a repetition rate of one to three times. Thus, the break signal in schools can be deliberately set to only one repetition. In the same way, the total signal can be set to continuous repetition, with the DIN tone being played only once while subsequent speech messages are played up to three times.  The sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) to approximately 92dB (A).

Fire detector O²T/FSp Serie IQ8Quad.
It incorporates 3 technologies: thermostatic, thermo-velocimetric and smoke optic with 70° offset optics to detect any type of smoke (even invisible and dark).
Approval EN54, VdS G205111.

  • Loop powered – no need for external power supply
  • Individual control of the Sounder
  • Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools (school bell) etc.
  • Soft start option, ideal for hospitals and nursing homes
  • No additional short address
  • Automatic synchronization of various IQ8Quad alarm signaling devices
  • Maximum sound level: 92 dB (A) at 1 m
  • Maximum sound pressure can be set
  • Multiple signal components can be combined to one signal template
  • Signal template and repetition rates can be set
  • 20 different signal tones, incl. DIN-tone
  • Low power consumption
  • Speech message with sounder
  • Loop powered – no need for external power supply
  • No additional short address
  • Automatic synchronization of various IQ8Quad alarm signaling devices
  • Maximum sound level: 92 dB (A) at 1 m
  • Maximum sound pressure can be set
  • Multiple signal patterns can be combined to one signal
  • Signal pattern and repetition rates can be set
  • 20 different signal tones, incl. DIN-tone
  • Speech messages can be played in up to 5 languages
  • 5 alarm messages per languages are preprogrammed
  • Up to 26 different languages are available

In addition to smoke detection with conventional O²T multisensor technology, the detector is provided with a built-in voice alarm device a build-in flash lamp and a built-in alarm signaling device. It can be set to eight different levels of detection.
Multisensor detectors with two built-in optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation for detecting everything from smouldering fires to open fires with consistent response performance. Smoke sensor signal identification to ensure smoke classification and
reduction of false alarms caused, for instance, by water vapour or dust. Each detector is provided with an integrated isolator.

The alarm signaling device is activated by the control panel. No further short address needs to be allocated. It is programmed with tools 8000 as of software version 1.05. Alarm tone / speech message programming (depending on type). For detectors with speech message and / or alarm tone function with up to five language options, up to 4 signals can be programmed. Two signals are reserved for alarm signaling and evacuation in the case of fire. Two further signals can be programmed for other events. Each signal can consist of up to four signal
components, enabling one signal to be programmed as a DIN tone combined with subsequent speech messages in three different languages. Alarm tones can be chosen from a table with various tone types.

For application in schools, a break signal to signify the breaks between class can be activated. When the basic setting is selected, signals / signal components can be continuously repeated until the signaling function is interrupted by the control panel. They can also be programmed with a repetition rate of one to three times. Thus, the break signal in schools can be deliberately set to only one repetition. In the same way, the total signal can be set to continuous repetition, with the DIN tone being played only once while subsequent speech messages are played up to three times.

The sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) to approximately 92dB (A).

Details - O²T/FSp fire detector